Modem Industrial | 4G LTE Cellular Modems with European bands
USR-G786-E is an industrial 4G LTE cellular modems with European bands, and it can realize the data transmission between serial port and 4G network
Realize data transmission from user’s device
and network in bi-direction. Work mode: TCP Server/Client,
UDP Support two socket connections under TCP server mode
User-defined heartbeat packet and registry packet
The registered packet is sent to the server to identify the device,
and the heartbeat packet is sent to the server to identify the active state of the device.
Heartbeat packet is sent to serial port terminal for active data collection
The contents of register packet and heartbeat packet
and heartbeat interval can be modified by AT command
Can be configured by serial port AT command,
network AT command and SMS AT command.
RS485 in terminal type, lightning protection
1KV Anti-Surge 1KV
Power Isolation, power over-current protection
Can upgrade the firmware by remote management system
Impulse Testing
RS485 Power Supply 2KV
APN Private Network
Ensure the security of data transmission
Electrostatic Protection
Air±15KV
Contact ±8KV
Hardware Watchdog
Watchdog circuit, stable operation
without downtime in 24 hours
USR-G786-E is an Industrial serial cellular 4G LTE
modem with European band. It can realize
the data transmission between serial port
and 4G network
Realize data transmission from user’s device
and network in bi-direction. Work mode:
TCP Server/Client, UDP Support two
socket connections under TCP server mode
User-defined heartbeat packet and registry packet
The registered packet is sent to the server to
identify the device, and the heartbeat packet is
sent to the server to identify the active state
of the device. Heartbeat packet is sent to serial
port terminal for active data collection. The
contents of register packet and heartbeat packet
and heartbeat interval can be modified by
AT command
Can be configured by serial port AT command,
network AT command and SMS AT command.
RS485 in terminal type, lightning protection
1KV Anti-Surge 1KV
Power Isolation, power over-current protection
Can upgrade the firmware by remote management
system
Impulse Testing
RS485 Power Supply
2KV
APN Private Network
Ensure the security
of data transmission
Electrostatic
Protection
Air±15KV
Contact ±8KV
Hardware Watchdog
Watchdog circuit,
stable operation
without downtime
in 24 hours
Parameter |
Item |
Index |
|
Wireless Parameters |
Wireless standard |
FDD-LTE,TDD-LTE, HSPA+/WCDMA, GSM/GPRS/EDGE |
|
2G/3G/4G Band |
FDD-LTE |
Band 1/2/3/5/7/8/20 |
|
TDD-LTE |
Band38/40/41 |
||
HSPA+/WCDMA |
Band1/2/5/8 |
||
GSM/GPRS/EDGE |
Band2/3/5/8 |
||
Transmitting power |
TDD-LTE |
+23dBm(Power class 3) |
|
FDD-LTE |
+23dBm(Power class 3) |
||
WCDMA |
+24dBm(Power class 3) |
||
EDGE Band8 |
+27dBm(Power class E2) |
||
EDGE Band3 |
+26dBm(Power class E2) |
||
GSM Band8 |
+33dBm(Power class 4) |
||
GSM Band3 |
+30dBm(Power class 1) |
||
Antenna options |
SMA interface |
||
Hardware parameters |
Data interface |
RS232:2400bps - 460800bps |
|
RS485:2400bps - 230400bps |
|||
Working voltage |
DC 9V~36V |
||
Working current |
Average:72.64mA-99.11mA@12V Max:353.05mA@12V |
||
Work temperature |
-30℃- 75℃ |
||
Storage temperature |
-40℃- 95℃ |
||
Size(mm) |
111.51*94*25(L*W*H) |
||
Software parameters
|
Work mode |
Transparenttransmission mode,SMS mode |
|
Setting command |
AT+Command |
||
Network protocol |
TCP/UDP |
||
MaximumTCPconnection number |
2 |
||
User configuration |
Serial AT command,Network AT command, SMS AT command |
||
Software function |
Domain name resolution DNS |
Support |
|
Modbus protocol |
Modbus RTU to Modbus TCP |
||
Transmission Mode |
TCP Client/TCP Server/UDP Client |
||
SMS functions |
Support |
||
Heartbeat package |
Support |
||
Registration packagemechanism |
Custom registration package/ICCID /IMEI |
||
User-cloud service |
Support |
||
Remote update |
Support |
[User Manual] USR-G786-E Software Manual
[RoHS Certificates] RoHS Certificates for 4G LTE modem
[CE Certificates] CE Certificates for 4G LTE Modem
[Datasheet] USR-G786 Datasheet
[Certificate] CE Certificate USR-G786
[Certificate] CE RoHS Certificate USR-G786
[Certificate] IC Certificate USR-G806
Remotely Controlling and Monitoring ReclosersMay 05,2022
A rapid short circuit in a power network creates two primary issues for Utility Companies: damage to power control systems and loss of revenue. Transients resulting from the short circuit have the potential to damage high value and critical power controls system such as regional substations and feeder stations.
Remote intelligent meter readingMay 05,2022
In nowadays, the large number of various meters are dispersed in different locations, some of which are remote and difficult to access, a remote meter reading system is urgently needed to relieve staff of utilities from heavy but inefficient tasks.Traditionally, the utilities companies used to hire thousands of meter readers to go around to read the meter, and always spend much money on traffic and labor.
title | update date | operation |
---|
Official Online Shop
Related Products
Request a quote get more products/services/promotions.We will reply to you in a business day.
(Your email address will not be shared with a third party.)