Support Center
The Delay Time of Ethernet Module USR-K7
2020-05-12

Question:

Ethernet module USR-K7
I plan to use USR-K7 model for converting serial data to Ethernet.
I have to know the delay time.

 

Answer:

You can set the data packing time with the AT command.
The default packing time is 0.
AT+UARTTL1
Function: set / query user custom packaging mechanism
Query instruction format:
AT+ UARTTL1<CR><CR><LF>+OK=<time,length><CR><LF>
Set the instruction format:
AT+ UARTTL1=<time,length> <CR><CR><LF>+OK<CR><LF>
parameter:
Time: byte interval: 0 ms ~ 255 ms; N according to the performance settings of each platform.
Length: The maximum length of the packet is 1~1460 bytes. When the received data byte interval has not expired and the received packet length reaches the maximum length, it is packaged and sent.
Example: AT+UARTTL1=25,100

 

Question:

If for example the packing time is 0 and I send 20 bytes by TTL UART, what will be the delay time until it will be sent threw UDP?

 

Answer:

The delay time is 1ms.

Industrial loT Gateways Ranked First in China by Online Sales for Seven Consecutive Years **Data from China's Industrial IoT Gateways Market Research in 2023 by Frost & Sullivan
Subscribe
Be Honest, Do Best
Copyright © Jinan USR IOT Technology Limited All Rights Reserved. Lu ICPB No. 16015649-5/ Sitemap / Privacy Policy