Products
IoT Gateways
Netcom Products
IoT Modules
PUSR CLoud
ODM/EMS
Pusr Cloud, a cloudplatform for the Internet of Things Zero programming comes with its own Internet of Things system.
200
+ Private Cloud project
Data localization
Business personalization
100k
+ Public Cloud registered
80% functions are free
White-labeling for VIP
LEARN MORE
KingView-A SCADA Software With 25+ Years Of Development History Nice Graphics display to monitor and Control Production flow System.
25
+ Development History
Data Collection, Analysis &
Management
100k
+ respond within 1
Perfect Alarm Monitoring &
Querying
LEARN MORE
PCB Design —— ODM/EMS We provide one-stop turnkey design service to help customers with the delivery of an out-of-the-box hardware platform that is fully tested and ready to use upon delivery.
10
+ years of experience
11 high-speed SMT
10 million pcs daily
200
+ Private Cloud project
ISO9001 cert.
Intelligent MES
LEARN MORE
Support Center
How do I test a Serial to Ethernet Converter?
2022-06-16

How do I test a Serial to Ethernet Converter?

How to test the serial to Ethernet converter is a problem that many users must consider when starting a new product. Today, I will take the serial server USR-N510 of USR IOT as an example to analyze how to test the device.

The first step is the hardware connection.

The first step of debugging is to connect the serial to Ethernet converter to the computer through the serial cable. Connect the USR-N510 to the computer with a network cable and an RS485 serial port. After the connection is correct, use the matching power adapter to supply power to the serial to Ethernet converter.

The second step is to test the network

In the process of using the serial to Ethernet converter for the first time, the user sometimes encounters problems such as unable to open the web page or ping failure. Therefore, after the hardware connection is correct, the following operations need to be performed on the connected computer.

(1) Open the control panel of the computer, close the antivirus software and firewall

(2) Turn off the network card unrelated to debugging and keep the local connection

(3) After the serial to Ethernet converter is directly connected to the computer, it is necessary to set a static IP for the computer, which is in the same network segment as the IP of the N510, for example: 192.168.0.201.

The third step, the default parameter debugging

Taking N510 as an example, the default parameters are as follows

Model

USR-N510

Input

DC5~36V

Login

admin

Pwd

admin

Default IP

192.168.0.7

Subnet mask

255.255.255.0

Default gateway

192.168.0.1

Serial port baud rate

115200

After the above operations are confirmed to be correct, the data transmission test between the serial to Ethernet converter and the Ethernet can be carried out.

(1) Open the test software "USR-TCP232-Test.exe"

(2) Select TCP Client mode in the network setting area, input 192.168.0.7 for the IP address, after confirming that the hardware is connected to the serial port, enter the server port number to establish a TCP connection, the serial port baud rate is set to 115200, the serial port parameter is set to the parity bit None, Data bit 8, stop bit 1, click open to open the serial port.

At this point, the test of the USR-N510 is completed. I hope this serial to Ethernet converter can be used as an example to solve your debugging problems in the actual application process.