Products
IoT Gateways
Netcom Products
IoT Modules
PUSR CLoud
ODM/EMS
Pusr Cloud, a cloudplatform for the Internet of Things Zero programming comes with its own Internet of Things system.
200
+ Private Cloud project
Data localization
Business personalization
100k
+ Public Cloud registered
80% functions are free
White-labeling for VIP
LEARN MORE
KingView-A SCADA Software With 25+ Years Of Development History Nice Graphics display to monitor and Control Production flow System.
25
+ Development History
Data Collection, Analysis &
Management
100k
+ respond within 1
Perfect Alarm Monitoring &
Querying
LEARN MORE
PCB Design —— ODM/EMS We provide one-stop turnkey design service to help customers with the delivery of an out-of-the-box hardware platform that is fully tested and ready to use upon delivery.
10
+ years of experience
11 high-speed SMT
10 million pcs daily
200
+ Private Cloud project
ISO9001 cert.
Intelligent MES
LEARN MORE
Support Center
How to Use Two usr-tcp232-306 Devices to Connect the Instrument to the PC?
2020-05-14

Question:

Dear USR IOT Technical Support I have an instrument installed at the roof top. This instrument must be connected to a PC at the first floor. For this purpose, I have bought two usr-tcp232-306 devices to connect the instrument to the PC. The wiring diagram is as follow. 

wiring diagram of usr-tcp232-306

I have built this project but it did not work. Therefore I would like to have your suggestion how to get this project works well. I look forward to your help.

 

Answer: First connect 306 and computer with RS232 and network cable,search through M0.exe.

usr-tcp232-306 to usr-tcp232-306

The IP of this two 306 should be in the same network segment, u and set it work at DHCP/STATIC mode;

Set one(A) work at TCP server

Another work at TCP Client mode, the remote IP and remote port are the IP/port of A

Note:

 

Same baud-rate, stop bit, data bit, parity

 

usr-tcp232-306 to usr-tcp232-306

usr-tcp232-306 to usr-tcp232-306

Then connect this two 306 with network cable.

usr-tcp232-306 to usr-tcp232-306