WiFi Device Under https Client Mode Manual
2020-05-11

Overview

 

This manual introduces the https Client mode of high-performance WiFi product ( WiFi modules: A2, B2, D2 and serial to WIFI converters USR-W630, USR-W610, USR-W600, etc).

 

https Client mode: After enabling this function, user can send data or get data from https server. When using this function, user just needs to set related configuration by AT command or Web Server and module will package serial data into https protocol data packet then transmit them to https server.

1.Configuration

In this manual, we take USR-WIFI232-602 V2 as example to test.

 

Step 1: Enter Web Server. 602 V2 is in default settings(AP mode and IP address is 10.10.100.254), so we can connect PC to 602 V2 by WiFi connection then enter Web Server through 10.10.100.254 with username/password both are admin. (If user wants to configure module by AT command, user should connect PC to 602 by serial cable and refer to https://www.usriot.com/enter-serial-command-mode/ to enter AT command mode and send AT commands)

1.1.jpg

Step 2: Change module to STA mode and https Client mode.

step2.jpg

By AT command: AT+WMODE=STA, AT+ TMODE=httpsdclient

Step 3: Configure STA interface setting.

step3.jpg

By AT command: AT+WSSSID=AP’s SSID, AT+WSKEY=WPA2PSK,AES,AP’s password

 

Step 4: Configure https Client mode parameters. (We take our server test.usr.cn as example)

step4.jpg

By AT command: AT+ HTPMODE=new, AT+ HTPSV=test.usr.cn,80, AT+ HTPTP=GET, AT+ HTPURL=/2.php?, AT+ HTPHEAD=Content-type:text/html:charset=utf-8

 

Step 5: Reset the module.

step5.jpg

By AT command: AT+Z

Reliable products and services around you !
Subscribe
Be Honest, Do Best
Products Serial to Ethernet/WiFi
Cellular Modems
Cellular Routers
DIN Rail Devices
IoT Gateways
LoRa Modems
Ethernet Modules
WiFi Modules
4G Modules
Bluetooth Module
Support Downloads
Technical FAQ
Technical Support
Contact Us Email : inquiry@usriot.com
Tel : +86-531-88826739
Fax : +86-531-88826739-808
Copyright © Jinan USR IOT Technology Limited All Rights Reserved. / Sitemap / Privacy Policy