September 25, 2025 Anti-Interference Design of Industrial Computers in Smart Grids

Power Line Carrier Communication: Anti-Interference Design of Industrial Computers in Smart Grids
At the nerve endings of smart grids, Power Line Carrier Communication (PLC) is infiltrating every corner in the form of "invisible blood vessels." This technology, which utilizes existing power lines for data transmission, has become a core communication means in scenarios such as smart meters, distributed energy management, and smart homes, thanks to its advantages such as no need for additional wiring and wide coverage. However, the inherently strong interference environment of power lines—including 50Hz power frequency pulses, harmonic noise from high-power loads, and electromagnetic radiation noise—makes communication quality akin to navigating through a thunderstorm. How to achieve reliable transmission in complex electromagnetic environments has become a key proposition for the application of industrial computers in smart grids.

  1. The "Inherent Dilemma" of Power Line Carrier Communication
    The original design purpose of power lines is to transmit electrical energy, not data. Its communication environment can be described as "extremely challenging":
    Power Frequency Pulse Interference: Domestic 50Hz AC power generates two voltage peaks per cycle, creating fixed pulse noise at 100Hz with peak amplitudes exceeding 40V, directly drowning out low-level carrier signals.
    Dynamic Load Changes: From incandescent bulbs to variable frequency air conditioners, the impedance characteristics of different loads vary greatly. When a high-power motor starts, the line impedance may drop sharply from hundreds of ohms to 0.1 ohms, causing signal attenuation exceeding 60dB.
    Multipath Effects: The power line network acts as a natural "reflection chamber," where signals repeatedly reflect at branch nodes, creating multipath interference that results in intersymbol interference (ISI) and frequency-selective fading.
    Tight Spectrum Resources: The power line carrier frequency band in China is limited to 40-500kHz, with a single-channel bandwidth of only 4kHz. It needs to simultaneously carry multiple services such as meter reading, control, and monitoring, demanding extremely high spectrum utilization efficiency.
    Traditional narrowband PLC technologies (such as FSK and PSK modulation) struggle in the above environments. Tests by a provincial power grid show that the meter reading success rate of smart meters using traditional technologies is less than 65% in industrial areas and only around 82% in residential areas.
  2. Three Major Technological Breakthroughs in Anti-Interference Design
    2.1 Modulation Technology: From "Resisting Interference" to "Utilizing Interference"
    Modern PLC systems widely adopt Orthogonal Frequency Division Multiplexing (OFDM) technology, whose core idea is to divide the channel into hundreds of orthogonal subcarriers and achieve "avoiding harm and taking advantage" by dynamically allocating power and bit numbers. For example, in an application in an industrial park, an OFDM system can automatically avoid the 200-300kHz frequency band interfered with by frequency converters, increasing the effective data transmission rate from 1.2kbps with traditional technologies to 50kbps.
    More cutting-edge solutions combine OFDM with Trellis Coded Modulation (TCM). In a field test at a substation in Qingdao, this combined technology reduced the bit error rate from 10-3 to 10-6, approaching the level of optical fiber communication. Its principle is to improve the signal-to-noise ratio tolerance through coding gain, allowing the original data to be recovered through redundant coding even if some subcarriers are interfered with.
    2.2 Channel Equalization: Equipping Signals with "Adaptive Glasses"
    Power line channels have time-varying characteristics—the attenuation at the same location may differ by more than 30dB at different times. Adaptive equalization technology dynamically adjusts receiver parameters by monitoring channel responses in real time. In a renovation project in a urban village in Shenzhen, a PLC module using a Decision Feedback Equalizer (DFE) successfully compressed the signal attenuation fluctuation range from ±15dB to ±3dB, increasing the meter reading success rate to 99.2%.
    Intelligent notch filters are another innovation. Through the principle of series resonance, this technology can precisely target and suppress interference at specific frequencies (such as 100kHz harmonics generated by switching power supplies). In an application at a data center in Hangzhou, an intelligent notch filter suppressed noise in a specific frequency band by 25dB, extending the PLC communication distance from 150 meters to 400 meters.
    2.3 Forward Error Correction: Dressing Data in "Bulletproof Vests"
    In scenarios where noise is inevitable, Forward Error Correction (FEC) technology serves as the last line of defense. Low-Density Parity-Check (LDPC) codes are gradually replacing traditional Reed-Solomon codes due to their performance close to the Shannon limit. In an application at a new energy farm in Chengdu, LDPC coding reduced the retransmission rate from 12% to 0.3% while reducing redundant overhead by 30%.
    More complex solutions employ interleaving technology, which disperses continuous bit streams into different time slots for transmission. When encountering burst interference, the receiver can disperse errors into multiple codewords through deinterleaving and then correct them through FEC. In a test in a subway tunnel in Guangzhou, this technology shortened the interruption time of PLC communication from 5 seconds to 200 milliseconds when trains passed by.
  3. Anti-Interference Practice of the Industrial Computer USR-EG628
    As the "nerve center" of smart grids, industrial computers need to build a dual anti-interference system at both the hardware and software levels. Taking the USR-EG628 from USR IOT as an example, its design embodies three anti-interference philosophies:
    3.1 Hardware Redundancy: Building a "Safety Capsule" for Signals
    Multi-Mode Communication Backup: Integrating four communication methods—4G/5G, WiFi, Ethernet, and PLC—allows automatic switching to wireless channels when PLC is interrupted due to power line interference. In an application at a steel plant in Jinan, this redundant design increased data transmission reliability from 92% to 99.97%.
    Isolated Power Supply Design: Using DC-DC isolation modules and optocoupler isolation interfaces completely electrically isolates the controller from the power line, preventing power frequency interference from intruding through the power path. Tests show that the isolation design improved the controller's resistance to pulse interference by 40dB.
    Industrial-Grade Component Selection: Core chips operate in a wide temperature range of -40℃ to 85℃, and passive components such as capacitors and inductors use high-stability materials like X7R and NP0 to ensure stable performance in harsh electromagnetic environments.
    3.2 Software Intelligence: Equipping the Controller with an "Adaptive Brain"
    Dynamic Spectrum Sensing: An built-in spectrum analysis module can scan the 40-500kHz frequency band in real time and automatically avoid interfered frequency bands. In an application at a chemical park in Suzhou, this function enabled PLC communication to avoid frequency bands interfered with by frequency converters, extending the transmission distance from 200 meters to 800 meters.
    AI-Driven Channel Prediction: By learning historical channel data through LSTM neural networks, interference change trends can be predicted in advance. In a test at a smart community in Wuhan, an AI model successfully predicted channel degradation during peak evening electricity usage and adjusted modulation parameters in advance, maintaining a meter reading success rate of over 98%.
    Edge Computing Offloading: Moving some data processing tasks (such as data compression and protocol conversion) to the local side reduces the amount of data that needs to be transmitted. In an application at a data center in Nanjing, edge computing reduced PLC communication load by 65%, indirectly improving anti-interference capability.
    3.3 Protocol Optimization: Breaking the "Protocol Island"
    Full Protocol Compatibility: Supporting over 20 industrial protocols such as Modbus RTU/TCP, DL/T645, and IEC 61850 enables seamless interconnection with smart meters, sensors, and other devices from different manufacturers. In an application at a comprehensive energy project in Zhengzhou, protocol compatibility reduced device interconnection time from 72 hours to 2 hours.
    Lightweight Protocol Stack: Developing a dedicated protocol stack tailored to the limited bandwidth of PLC compresses the protocol header overhead from 40 bytes in traditional TCP/IP to 8 bytes. In a test at a distributed photovoltaic power station in Xi'an, the lightweight protocol increased effective data transmission efficiency by 300%.
    Secure Encryption Mechanism: Using AES-128 encryption algorithm and dynamic key update mechanisms prevents data eavesdropping or tampering. In an application at a smart park in Chongqing, encryption technology successfully intercepted 12 simulated attacks, ensuring the security of energy data.
  4. From Anti-Interference to "Dancing with Interference": Future Technological Evolution
    As smart grids evolve towards the "dual carbon" goals, PLC technology is upgrading from "resisting interference" to "utilizing interference":
    Integration of Power Line and Wireless Networks: Through PLC-WiFi6/LoRa gateways, deep integration of power line and wireless networks is achieved. In an application at the Asian Games Village in Hangzhou, this integrated network reduced the delay in smart lighting control from 500 milliseconds to 50 milliseconds.
    Digital Twin Channel Modeling: Using AI to build digital twins of power line channels enables interference source localization and channel capacity prediction. In a pilot project in the Qianhai area of Shenzhen, digital twin technology increased PLC network planning efficiency by 60%.
    Energy Internet Communication Protocol: Developing a unified communication protocol for the energy internet supports plug-and-play of multi-source heterogeneous devices such as photovoltaics, energy storage, and electric vehicles. The "Energy Router" standard being promoted by State Grid has included PLC as one of its core communication methods.
    When we see smart streetlights adjusting their brightness in real time through power line communication on the Bund in Shanghai and witness distributed energy achieving millisecond-level scheduling through PLC in the Xiong'an New Area, it is foreseeable that anti-interference design is not just a technological challenge but also a catalyst for the evolution of smart grids. In this transformation, industrial computers are shifting from "passively adapting to interference" to "actively shaping channels," providing crucial support for building a clean, low-carbon, safe, and efficient modern energy system.