February 16, 2026
Shielding Design of Ind'l Computer vs 10kV EMP: Building an EMP Shield for Safety
Smart Steel Blast Furnace Monitoring: Industrial Computer's Shielding Design Against 10kV EMP - Building an "EMP Shield" for Industrial Safety
1. The "Invisible Killer" of Blast Furnaces: Threat of 10kV EMP
In the steel industry, blast furnaces are core for ironmaking, affecting production efficiency and cost. However, their monitoring systems face an "invisible killer" - 10kV EMP interference. This comes from dense electrical equipment (e.g., inverters, welders) and spatial radiation from power frequency (50Hz) power over long distances. When EMP reaches 10kV, it can penetrate ordinary shields, causing data distortion, equipment malfunctions, or permanent damage. Customer Insight: "High repair costs and unbearable production losses if the monitoring system fails. But EMP is invisible. How to ensure effective shielding?" - This is a real concern of steel enterprise technical leaders.
2. EMP's "Destruction Path": Three Stages from Penetration to Destruction
To understand shielding design, we need to dissect EMP's destruction mechanism. According to military electronic information system protection standards, EMP damages equipment in three stages:
Penetration Stage: EMP enters equipment through antennas, cable gaps, or metal structures, forming induced currents.
Transmission Stage: Induced currents travel along circuits to sensitive components (e.g., integrated circuits, sensors).
Destruction Stage: High energy density causes component breakdown, data loss, or system paralysis. Case Study: A steel enterprise's blast furnace monitoring system, without special shielding, suffered EMP impact during a thunderstorm. 32 temperature sensors had abnormal data, leading to production halt and losses over 2 million yuan.
3. Shielding Design's "Golden Rules": Layered Defense and Material Selection
For 10kV EMP, shielding design follows the "layered defense" principle, building a protection system at spatial, equipment, and circuit levels, optimizing shielding effectiveness with material properties.
3.1 Spatial Shielding: The "First Line of Defense" Against EMP
Goal: Place the blast furnace monitoring system in an EMP shielding room to attenuate spatial radiation energy. Design Points:
Material: Use high-conductivity (e.g., copper, aluminum) or high-permeability (e.g., soft iron, silicon steel) materials. Copper's skin depth is only 0.094mm at 500kHz, suitable for high-frequency shielding; ferromagnetic materials are better for low-frequency magnetic fields (e.g., 50Hz power frequency).
Structure: Double-layer shielding room with inner copper plate (≥1mm thick) and outer iron plate (≥3mm thick), filled with metal wool to absorb residual energy. According to MIL-STD-461/462, this can attenuate pulse electric fields by ≥85dB and magnetic fields by ≥60dB.
Gap Treatment: Install honeycomb shielding nets on all doors, windows, and vents with pore size ≤λ/20 (λ is the electromagnetic wavelength) to avoid "leakage wave" effects.
3.2 Equipment Shielding: The "Second Line of Defense" for Key Components
Goal: Locally shield core equipment like industrial computer and sensors to prevent induced current intrusion. Design Points:
Chassis Design: Use all-metal chassis (e.g., aluminum alloy) with nickel plating for enhanced conductivity. Seal gaps with conductive adhesive or beryllium copper springs to ensure contact resistance ≤0.1Ω.
Filter Design: Install EMI filters at power inlets to suppress conducted interference. Filters should meet:
Insertion loss: ≥40dB in the 10kHz - 10MHz band.
Withstand voltage: ≥10kV (for pulse impact).
Leakage current: ≤1mA (for safety).
Grounding System: Use single-point grounding with ground resistance ≤2Ω. Connect shields, filters, and equipment enclosures to grounding electrodes via low-impedance conductors (e.g., copper bars) to avoid ground loop interference.
3.3 Circuit Shielding: The "Third Line of Defense" for Signal Lines
Goal: Shield signal lines (e.g., temperature sensor lines, pressure transmitter lines) of the monitoring system to prevent induced current transmission. Design Points:
Cable Selection: Use twisted-pair shielded cables (e.g., RVVP type) with shield coverage ≥95%. The twisted-pair structure cancels common-mode interference, and the shield attenuates EMP energy.
Shield Treatment: Ground the shield at the signal source and receiver ends only to avoid ground loops. If the line length exceeds 10 meters, add grounding connections at intermediate points.
Signal Isolation: Install isolation amplifiers or optocouplers at signal inputs to electrically isolate monitoring signals from industrial computers and block induced current paths.
4. USR-EG628 Industrial Computer: The "Invisible Helper" for Anti-Interference Design
In shielding design, the industrial computer's performance directly affects system stability. USR-EG628, a comprehensive and expandable ARM industrial computer with "edge computing + PLC programming + local configuration" integration, is ideal for blast furnace monitoring systems:
Hardware-Level Anti-Interference
Integrated EMI filter circuit at power inlets to suppress conducted interference.
All-metal chassis supporting single-point grounding with ground resistance ≤2Ω.
4 RS485 interfaces, each independently isolated with isolation voltage ≥2kV to avoid port interference.
Software-Level Optimization
Built-in watchdog timer to monitor program operation and prevent program runaway due to EMP.
Supports digital filtering algorithms (e.g., average value filtering, median filtering) to eliminate pulse noise in signals.
Provides graphical configuration tools for quick definition of signal mapping relationships, reducing manual configuration errors.
Protocol Compatibility
Supports industrial protocols like Modbus RTU/TCP, Profinet, and EtherNet/IP for seamless integration with various sensors and actuators in the blast furnace monitoring system.
Supports IoT protocols like MQTT and HTTP for real-time data upload to the cloud for remote monitoring. Application Example: In a steel enterprise's blast furnace monitoring project, USR-EG628 achieved anti-interference through:
EMI filter at power inlet reducing conducted interference from 10kV to ≤1V.
RVVP shielded cables for signal lines with single-ended grounding of shields, achieving common-mode interference attenuation ≥40dB.
Industrial computer chassis grounding resistance ≤1.5Ω to avoid ground loops.
Software-enabled digital filtering algorithms eliminating pulse spikes in signals. The system ran fault-free for 180 days with a data accuracy rate of 99.97%.
5. From "Passive Defense" to "Active Early Warning": Future Trends in Shielding Design
With Industry 4.0, blast furnace monitoring systems need to upgrade from "anti-interference" to "intelligent protection". Future shielding design will have two trends:
Real-Time Monitoring and Dynamic Adjustment
Integrate EMP sensors to monitor spatial radiation intensity in real-time and adjust shielding system parameters (e.g., increase filter insertion loss, optimize ground resistance) for "adaptive protection".
Digital Twin and Predictive Maintenance
Build a digital twin model of the blast furnace monitoring system to simulate EMP propagation paths and destruction effects, identify weak points in advance, and optimize design. Use AI algorithms to analyze historical data and predict equipment failure risks for "preventive maintenance".
6. Building an "EMP Safety Net" for the Steel Industry
In smart steel construction, the anti-interference ability of blast furnace monitoring systems directly relates to production safety and efficiency. Through layered shielding design and hardware optimization of industrial computers like USR-EG628, we can effectively resist 10kV EMP impacts, providing stable and reliable data support for blast furnace operation. When EMP is no longer an "invisible killer" and monitoring systems shift from "passive defense" to "active defense", steel enterprises can truly achieve intelligent transformation - not just a technological upgrade but a solemn commitment to production safety.
Industrial loT Gateways Ranked First in China by Online Sales for Seven Consecutive Years **Data from China's Industrial IoT Gateways Market Research in 2023 by Frost & Sullivan
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.